811 Consolidated Service Invoice/Statement (007030)
This is the standard X12 007030 spec, with 30 loops and 138 segment positions, as OpenEDI JSON, an ediFabric C# template and an ediFabric Native model. To change it for a trading partner, customize it in the EDI Spec Builder.
Use the 811 spec in your code
ediFabric .NET
Add the C# template and its common files to your project, or reference the template NuGet package, and read 811 files into TS811 objects. See ediFabric .NET.
ediFabric Native
Map version 007030 to the Native model with set_map, then parse 811 files to JSON from Python, Java, C or C#. See Convert between EDI and JSON.
OpenEDI
Select Customize in Spec Builder to copy the spec under your own name, change it for your partner, and parse files against it in EdiNation, ediFabric Native or ediFabric Cloud. Read about OpenEDI.
Generate 811 classes in Python, Java, Node.js, Go, Rust or C
ediFabric Native returns each 811 as JSON, with the property names of the OpenEDI schema. To work with that JSON as typed objects, generate classes from the OpenEDI file in your language and deserialize the JSON into TS811. Serialize the objects back to JSON to build EDI with ediFabric Native. The classes keep the loops, segments, lengths and code lists, but not the EDI data formats, so validate files with ediFabric Native. Read more in Generate a class from OpenEDI.
Python: datamodel-code-generator. Node.js: openapi-typescript. Java, Go, Rust and C: OpenAPI Generator.
811 structure
Loops and segments of the standard 811, with their usage and maximum repeats.
| ID | Name | Usage | Max use |
|---|---|---|---|
| ST | Transaction Set Header | Mandatory | 1 |
| BIG | BIG | Mandatory | 1 |
| NTE | NTE | Optional | 100 |
| CUR | CUR | Optional | 1 |
| REF | REF | Optional | 99999 |
| PER | PER | Optional | 3 |
| ITD | ITD | Optional | 99999 |
| DTM | DTM | Optional | 10 |
| TXI | TXI | Optional | 99999 |
| Loop N1 | N1 | Optional | 99999 |
| N1 | N1 | Mandatory | 1 |
| N2 | N2 | Optional | 2 |
| N3 | N3 | Optional | 2 |
| N4 | N4 | Optional | 1 |
| REF | REF | Optional | 12 |
| PER | PER | Optional | 3 |
| DMG | DMG | Optional | 1 |
| Loop FA1 | FA1 | Optional | 99999 |
| FA1 | FA1 | Mandatory | 1 |
| FA2 | FA2 | Mandatory | 99999 |
| Loop HL | HL | Mandatory | 99999 |
| HL | HL | Mandatory | 1 |
| Loop LX | LX | Optional | 99999 |
| LX | LX | Mandatory | 1 |
| VEH | VEH | Optional | 1 |
| SI | SI | Optional | 8 |
| PID | PID | Optional | 200 |
| MEA | MEA | Optional | 20 |
| REF | REF | Optional | 99999 |
| AMT | AMT | Optional | 99999 |
| DTM | DTM | Optional | 8 |
| TXI | TXI | Optional | 99999 |
| Loop QTY | QTY | Optional | 10 |
| QTY | QTY | Mandatory | 1 |
| SI | SI | Optional | 1 |
| Loop NM1 | NM1 | Optional | 1 |
| NM1 | NM1 | Mandatory | 1 |
| N2 | N2 | Optional | 2 |
| N3 | N3 | Optional | 2 |
| N4 | N4 | Optional | 1 |
| REF | REF | Optional | 99999 |
| PER | PER | Optional | 99999 |
| TXI | TXI | Optional | 99999 |
| DMG | DMG | Optional | 1 |
| Loop ITA | ITA | Optional | 99999 |
| ITA | ITA | Mandatory | 1 |
| DTM | DTM | Optional | 1 |
| REF | REF | Optional | 5 |
| Loop IT1 | IT1 | Optional | 999999 |
| IT1 | IT1 | Mandatory | 1 |
| SI | SI | Optional | 2 |
| PID | PID | Optional | 200 |
| MEA | MEA | Optional | 20 |
| INC | INC | Optional | 1 |
| TXI | TXI | Optional | 99999 |
| REF | REF | Optional | 99999 |
| DTM | DTM | Optional | 10 |
| MSG | MSG | Optional | 99999 |
| CAD | CAD | Optional | 1 |
| YNQ | YNQ | Optional | 99999 |
| LQ | LQ | Optional | 99999 |
| LCD | LCD | Optional | 99999 |
| Loop AMT | AMT | Optional | 99999 |
| AMT | AMT | Mandatory | 1 |
| DTM | DTM | Optional | 1 |
| Loop QTY | QTY | Optional | 99999 |
| QTY | QTY | Mandatory | 1 |
| SI | SI | Optional | 1 |
| Loop ITA | ITA | Optional | 99999 |
| ITA | ITA | Mandatory | 1 |
| DTM | DTM | Optional | 1 |
| REF | REF | Optional | 5 |
| Loop NM1 | NM1 | Optional | 99999 |
| NM1 | NM1 | Mandatory | 1 |
| N2 | N2 | Optional | 2 |
| N3 | N3 | Optional | 2 |
| N4 | N4 | Optional | 1 |
| PER | PER | Optional | 3 |
| NX2 | NX2 | Optional | 99999 |
| DMG | DMG | Optional | 1 |
| REF | REF | Optional | 99999 |
| LCD | LCD | Optional | 99999 |
| Loop SLN | SLN | Optional | 99999 |
| SLN | SLN | Mandatory | 1 |
| SI | SI | Optional | 2 |
| PID | PID | Optional | 200 |
| MEA | MEA | Optional | 20 |
| CUR | CUR | Optional | 1 |
| INC | INC | Optional | 1 |
| ITA | ITA | Optional | 10 |
| TXI | TXI | Optional | 99999 |
| REF | REF | Optional | 99999 |
| PER | PER | Optional | 3 |
| DTM | DTM | Optional | 10 |
| AMT | AMT | Optional | 15 |
| MSG | MSG | Optional | 99999 |
| Loop QTY | QTY | Optional | 99999 |
| QTY | QTY | Mandatory | 1 |
| SI | SI | Optional | 1 |
| Loop NM1 | NM1 | Optional | 99999 |
| NM1 | NM1 | Mandatory | 1 |
| N2 | N2 | Optional | 2 |
| N3 | N3 | Optional | 2 |
| N4 | N4 | Optional | 1 |
| REF | REF | Optional | 8 |
| PER | PER | Optional | 3 |
| DMG | DMG | Optional | 1 |
| Loop TCD | TCD | Optional | 99999 |
| TCD | TCD | Mandatory | 1 |
| SI | SI | Optional | 2 |
| TXI | TXI | Optional | 99999 |
| ITA | ITA | Optional | 99999 |
| Loop QTY | QTY | Optional | 99999 |
| QTY | QTY | Mandatory | 1 |
| SI | SI | Optional | 1 |
| Loop USD | USD | Optional | 99999 |
| USD | USD | Mandatory | 1 |
| SI | SI | Optional | 2 |
| ITA | ITA | Optional | 2 |
| TRF | TRF | Optional | 18 |
| Loop QTY | QTY | Optional | 99999 |
| QTY | QTY | Mandatory | 1 |
| SI | SI | Optional | 1 |
| Loop III | III | Optional | 99999 |
| III | III | Mandatory | 1 |
| DTP | DTP | Optional | 5 |
| AMT | AMT | Optional | 5 |
| PCT | PCT | Optional | 5 |
| NX2 | NX2 | Optional | 5 |
| REF | REF | Optional | 5 |
| Loop LQ | LQ | Optional | 99999 |
| LQ | LQ | Mandatory | 1 |
| AMT | AMT | Optional | 5 |
| PCT | PCT | Optional | 5 |
| Loop FA1 | FA1 | Optional | 99999 |
| FA1 | FA1 | Mandatory | 1 |
| FA2 | FA2 | Mandatory | 99999 |
| TDS | TDS | Mandatory | 1 |
| Loop ITA | ITA | Optional | 99999 |
| ITA | ITA | Mandatory | 1 |
| DTM | DTM | Optional | 1 |
| REF | REF | Optional | 5 |
| Loop BAL | BAL | Optional | 99999 |
| BAL | BAL | Mandatory | 1 |
| DTM | DTM | Optional | 1 |
| Loop N1 | N1 | Optional | 99999 |
| N1 | N1 | Mandatory | 1 |
| Loop BAL | BAL | Optional | 99999 |
| BAL | BAL | Mandatory | 1 |
| DTM | DTM | Optional | 1 |
| Loop ITA | ITA | Optional | 99999 |
| ITA | ITA | Mandatory | 1 |
| DTM | DTM | Optional | 2 |
| AMT | AMT | Optional | 1 |
| SI | SI | Optional | 2 |
| REF | REF | Optional | 5 |
| CUR | CUR | Optional | 1 |
| Loop LX | LX | Optional | 99999 |
| LX | LX | Mandatory | 1 |
| REF | REF | Optional | 1 |
| Loop AMT | AMT | Optional | 99999 |
| AMT | AMT | Mandatory | 1 |
| DTM | DTM | Optional | 1 |
| Loop ITA | ITA | Optional | 99999 |
| ITA | ITA | Mandatory | 1 |
| DTM | DTM | Optional | 1 |
| CTT | CTT | Optional | 1 |
| SE | Transaction Set Trailer | Mandatory | 1 |